Our MR safety program is constantly evaluated for any new risks as we continue to provide a safe environment for our patients. We provide a secure, gated parking lot where patients are allowed in by the receptionist. Prior to the exam, our MR technologist performs a thorough health risk assessment by asking a list of questions to alert of any contraindications. While this may seem repetitive, we may ask the same questions to be sure we clearly understand your medical history and any possible risks for MRI.
We offer an MRI machine specifically for patients that may be claustrophobic which provides a little extra room to help patients with claustrophobic tendencies and anxiety. We provide earplugs as the noise of the magnets can be loud in the machine, or we can also provide music to help ease patient nerves and cut down noise. Patients always have a call button to alert a technologist to any problems or needs during the exam. Once complete, our Radiologist reviews the images and dictates the reports that will be sent to your healthcare provider.
Both have risks but are relatively safe procedures. MRI scan cost is comparatively higher than that of the CT scan. The exact time required depends on whether you need a contrast dye for the procedure, but MRIs always require more time for the scan.
CT scans produce excellent detail used to diagnose osteoarthritis and fractures. Joseph Spine is an advanced center for spine, scoliosis and minimally invasive surgery. Brain — CT is used when speed is important, as in trauma and stroke. MRI is best when the images need to be very detailed, looking for cancer, causes of dementia or neurological diseases, or looking at places where bone might interfere.
Now if that string was connected to something on the other side, it would start to pull on that side. In this respect it behaves like a small bar magnet. When the body is placed in a strong magnetic field, such as an MRI scanner, the protons' axes all line up. This uniform alignment creates a magnetic vector oriented along the axis of the MRI scanner. MRI scanners come in different field strengths, usually between 0.
When additional energy in the form of a radio wave is added to the magnetic field, the magnetic vector is deflected. The radio wave frequency RF that causes the hydrogen nuclei to resonate is dependent on the element sought hydrogen in this case and the strength of the magnetic field. The strength of the magnetic field can be altered electronically from head to toe using a series of gradient electric coils, and, by altering the local magnetic field by these small increments, different slices of the body will resonate as different frequencies are applied.
When the radiofrequency source is switched off the magnetic vector returns to its resting state, and this causes a signal also a radio wave to be emitted. It is this signal which is used to create the MR images. Receiver coils are used around the body part in question to act as aerials to improve the detection of the emitted signal. The button is connected to the venting system. If the button is pressed, a valve opens the venting tube. The Helium is then safely released to the outside of the hospital.
The loss of Helium warms the magnet and stops the superconductivity. The wires now develop a resistance to the current flow which then stops. Without current flow, there will no longer be magnetism. The magnet now has been successfully quenched. You should not use the emergency quench button for every type of emergency. Quenching results in the loss of Helium which is extremely expensive to replace.
Furthermore, the process of quenching can damage the magnet which can take a long time to repair, making the MRI unavailable for other patients. Most emergencies in the MRI room will not need you to press the quench button.
Other emergencies you can manage by taking the patient to a room located next to the MRI machine, where you can safely use standard hospital equipment. However, in certain rare situations you may have to stop the magnetism by quenching the magnet. For an example, just imagine that someone, by mistake, brought in an steel oxygen cylinder near the MRI machine.
It is important to recognise that the magnetic field of the MRI machine extends beyond the patient scanning table. Now that the magnetic field is gone, you can easily remove the steel cylinder. During a quench, certain conditions such as blockage of the venting pipe can result in Helium getting released into the room containing the MRI machine rather than being released to the outside of the building.
The liquid Helium that enters the room will rapidly become a gas at room temperature and will rapidly expand to fill the room. There are some risks to patient and staff associated with Helium release into the MRI room. One consequence can be quite funny. This happens because Helium has a low density and this makes sound travel faster.
If you want to hear a sample of a helium voice, I suggest that you visit YouTube. While you are at Youtube. A much more serious consequence is that the Helium can push the oxygen to the bottom of the room resulting in hypoxia to the patient and anyone else in the room. Therefore, during quench, it is important to open the door of the MRI room to let the Helium out.
One must also calmly but quickly evacuate the patient and staff. I have only given a very brief introduction to quenching. You must prepare for this rare eventuality using information from your hospital policies.
A small note to end this section: While reading around to write about the MRI machine, I was shocked to read news articles that say that the worlds Helium supply is diminishing. This news is making me wonder about the Helium that is used to inflate party balloons that float. As you may know, balloons filled with Helium float in the air because Helium has a low density. They are beautiful to watch. But I wonder if we should be wasting such a useful resource on floating party balloons?
If you have been next to or inside an MRI machine as a patient! However, if you have only been inside the MRI control room, you may not appreciate how loud it is. Furthermore, the MRI machine produces a large variety of different sounds. As mentioned before, the MRI machine has an extremely strong magnet, shown as the green coil below. This magnet produces a field that is equally strong everywhere. The gradient coils create a gradient by producing a small magnetic field within the main magnetic field.
The two magnetic fields interact and result in the magnetic gradient. The gradients that I have shown in our discussions have been simplified greatly. In reality there are many gradient coils and as the MRI machine scans different parts of the body, the coils work together to create very complex gradient fields.
As the MRI machine scans different areas of the body, it changes the gradients as necessary. The changes of the gradients are made by rapidly changing the magnetic fields produced in the gradient coils. The gradient coils have a tough job to do.
When the gradient coils produce magnetic fields to alter the main magnetic field, due to the huge magnetic forces involved, they move slightly. The MRI machine changes the gradients very rapidly in complex ways. This causes the gradient coils to rapidly move slightly vibrate. The vibrating gradient coils now produce sound red lines.
I see the MRI machine as a gigantic guitar, the gradient coils being the guitar strings. As the MRI creates complex gradients, the guitar strings gradient coils vibrate, producing the most amazing variety of tunes. If you have access to Youtube. Make sure you click on more than one video, so that you can hear the wide variety of sounds produced. Putting amusement aside, gradient coil noise is an huge problem with current MRI scanners.
It is loud enough to require patients and staff to wear ear protection. This website is primarily written for personnel working in anesthetics. However, I am aware that there are many thousands of non anaesthesia visitors as well who are of course most welcome. The next section is primarily for those in anesthetics, so some of you might wish to leave us here. Providing anaesthesia services for MRI is very challenging. Only those who have the relevant expertise should be involved in the unique world of MRI.
The focus of this website is mainly non clinical and the discussion that follows is therefore very basic and may not be accurate for your clinical setting. Therefore, please do not rely on the information here for actual patient care. The MRI machine can get in the way of anaesthesia, and the reverse is also true, where provision of anaesthesia can mess up MRI scans. However, for the sake of producing good images and keeping the patient safe, the couple needs to work together, taking care not to upset each other.
The MRI machine may be some located some distance away from the operation theatres. The location of the MRI room has to take into account many considerations. The MRI magnet can weigh — kilograms — pounds and therefore needs to be on a sturdy floor. One also needs to choose an area that minimises electrical , magnetic , and vibration interference. All this means that the MRI may be installed in a room that is distant from your normal area of work e.
If there is an emergency, it may be difficult to get appropriate help and equipment in an hurry. Therefore, you and your team should have the necessary skills to cope with emergencies.